Gamma - Glutamyltranspeptidase 1 ELISA Test Kit Sheep High Specificity For Accurate Quantitative Detection

China Shanghai Korain Biotech Co., Ltd certification
China Shanghai Korain Biotech Co., Ltd certification
Providing high quality products、perfect after-sales service, and try best to meet the requirement of customers. We are very willing to continue long-term cooperation.

—— Tommy

We have confidence in working with you to expand the market one more year.

—— Lilis

I'm Online Chat Now

Gamma - Glutamyltranspeptidase 1 ELISA Test Kit Sheep High Specificity For Accurate Quantitative Detection

Gamma - Glutamyltranspeptidase 1 ELISA Test Kit Sheep High Specificity For Accurate Quantitative Detection
Gamma - Glutamyltranspeptidase 1 ELISA Test Kit Sheep High Specificity For Accurate Quantitative Detection

Large Image :  Gamma - Glutamyltranspeptidase 1 ELISA Test Kit Sheep High Specificity For Accurate Quantitative Detection

Product Details:

Place of Origin: Shanghai, China
Brand Name: BT Lab
Certification: CE, ISO9001:2005, MSDS
Model Number: Cat.No E0203Sh

Payment & Shipping Terms:

Minimum Order Quantity: Negotiation
Price: Negotiation
Packaging Details: Wrapped with ice pack and styrofoam package
Delivery Time: 1-3 business days, bulk order within one week
Supply Ability: Western Union, T/T
Detailed Product Description
Discount: Available Sample: Serum,plasma,urine,tissue,cell Culture Supernatant
Known As: GGT1 Assay Principle: Sandwich
OEM: Acceptable Assay Time: 2 Hours
High Light:

elisa assay kit

,

elisa reagent kit

Sheep High Specificity Gamma-glutamyltranspeptidase 1 ELISA Test Kit For Accurate Quantitative Detection

 

Cat.No E0203Sh

Standard Curve Range: 0.3ng/ml - 90ng/ml

Sensitivity: 0.17ng/ml

Size: 96 wells

Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

*This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.

 

Assay Procedure

1. Prepare all reagents, standard solutions and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature.

2. Determine the number of strips required for the assay. Insert the strips in the frames for use. The unused strips should be stored at 2-8°C.

3. Add 50μl standard to standard well. Note: Don’t add antibody to standard well because the standard solution contains biotinylated antibody.

4. Add 40μl sample to sample wells and then add 10μl anti-GGT1 antibody to sample wells, then add 50μl streptavidin-HRP to sample wells and standard wells ( Not blank control well ). Mix well. Cover the plate with a sealer. Incubate 60 minutes at 37°C.

5. Remove the sealer and wash the plate 5 times with wash buffer. Soak wells with at least 0.35 ml wash buffer for 30 seconds to 1 minute for each wash. For automated washing, aspirate all wells and wash 5 times with wash buffer, overfilling wells with wash buffer. Blot the plate onto paper towels or other absorbent material.

6. Add 50μl substrate solution A to each well and then add 50μl substrate solution B to each well. Incubate plate covered with a new sealer for 10 minutes at 37°C in the dark.

7. Add 50μl Stop Solution to each well, the blue color will change into yellow immediately.

8. Determine the optical density (OD value) of each well immediately using a microplate reader set to 450 nm within 10 minuets after adding the stop solution.

 

Summary

1. Prepare all reagents, samples and standards.

2. Add sample and ELISA reagent into each well. Incubate for 1 hour at 37°C.

3. Wash the plate 5 times.

4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.

5. Add stop solution and color develops.

6. Read the OD value within 10 minutes.

 

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.

Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision.

CV(%) = SD/mean x 100

Intra-Assay: CV<8%

Inter-Assay: CV<10%

 

Reagent Provided

Components Quantity
Standard Solution (96ng/ml) 0.5ml x1
Pre-coated ELISA Plate 12 * 8 well strips x1
Standard Diluent 3ml x1
Streptavidin-HRP 6ml x1
Stop Solution 6ml x1
Substrate Solution A 6ml x1
Substrate Solution B 6ml x1
Wash Buffer Concentrate (25x) 20ml x1
Biotinylated Sheep GGT1 Antibody 1ml x1
User Instruction 1
Plate Sealer 2 pics
Zipper bag 1 pic

 

Material Required But Not Supplied

  • 37°C±0.5°C incubator
  • Absorbent paper
  • Precision pipettes and disposable pipette tips
  • Clean tubes
  • Deionized or distilled water
  • Microplate reader with 450 ± 10nm wavelength filter

 

Calculation of Result

Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.