Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Company News
Home ProductsHuman ELISA Kit

Sandwich Type Human ELISA Kit Angiopoietin 4 Immunoassays Test Kit With Oem Service

China Shanghai Korain Biotech Co., Ltd certification
China Shanghai Korain Biotech Co., Ltd certification
Providing high quality products、perfect after-sales service, and try best to meet the requirement of customers. We are very willing to continue long-term cooperation.

—— Tommy

We have confidence in working with you to expand the market one more year.

—— Lilis

I'm Online Chat Now

Sandwich Type Human ELISA Kit Angiopoietin 4 Immunoassays Test Kit With Oem Service

Sandwich Type Human ELISA Kit Angiopoietin 4 Immunoassays Test Kit With Oem Service
Sandwich Type Human ELISA Kit Angiopoietin 4 Immunoassays Test Kit With Oem Service

Large Image :  Sandwich Type Human ELISA Kit Angiopoietin 4 Immunoassays Test Kit With Oem Service

Product Details:

Place of Origin: Shanghai, China
Brand Name: BT Lab
Certification: CE, ISO9001:2005, MSDS
Model Number: Cat.No E1263Hu

Payment & Shipping Terms:

Minimum Order Quantity: Negotiation
Price: Negotiation
Packaging Details: Wrapped with ice pack and styrofoam package
Delivery Time: 1-3 business days, bulk order within one week
Supply Ability: Western Union, T/T
Detailed Product Description
Custom: Available Storage: 2-8°C
Sensitivity: 7.73ng/L Standard Curve Range: 15ng/L - 3000ng/L
Assay Time: 2 Hours Delivery: Within 48 Hours
High Light:

enzyme immunoassay kit

,

enzyme assay kits

Sandwich Type Human Angiopoietin 4 Immunoassays Test Kit Highly Sensitive With Oem Service

 

Cat.No E1263Hu

 

Precautions

  • Prior to use, the elisa test kit and sample should be warmed naturally to room temperature 30 minutes.
  • This instruction must be strictly followed in the experiment.
  • Once the desired number of strips has been removed, immediately reseal the bag to protect the remain from deterioration. Cover all reagents when not in use.
  • Make sure pipetting order and rate of addition from well-to-well when pipetting reagents.
  • Pipette tips and plate sealer in hand should be clean and disposable to avoid cross-contamination.
  • Avoid using the reagents from different batches together.
  • Substrate solution B is sensitive to light, don’t expose substrate solution B to light for a long time.
  • Stop solution contains acid. Please wear eye, hand and skin protection when using this material. Avoid contact of skin or mucous membranes with kit reagent.
  • The elisa test kit should not be used beyond the expiration date.

 

*This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.

 

Intended Use

This sandwich kit is for the accurate quantitative detection of human Angiopoietin 4 (also known as ANG-4) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.

 

Reagent Provided

Components Quantity
Standard Solution (3200ng/L) 0.5ml x1
Pre-coated ELISA Plate 12 * 8 well strips x1
Standard Diluent 3ml x1
Streptavidin-HRP 6ml x1
Stop Solution 6ml x1
Substrate Solution A 6ml x1
Substrate Solution B 6ml x1
Wash Buffer Concentrate (25x) 20ml x1
Biotinylated human ANG-4 Antibody 1ml x1
User Instruction 1
Plate Sealer 2 pics
Zipper bag 1 pic

 

Specimen Collection

Serum Allow serum to clot for 10-20 minutes at room temperature. Centrifuge at 2000-3000 RPM for 20 minutes.

 

Plasma Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 2000-3000 RPM at 2 - 8°C within 30 minutes of collection.

 

Urine Collect by sterile tube. Centrifuge at 2000-3000 RPM for approximately 20 minutes. When collecting pleuroperitoneal fluid and cerebrospinal fluid, please follow the procedures above-mentioned.

 

Cell Culture Supernatant Collect by sterile tubes when examining secrete components. Centrifuge at 2000-3000 RPM for approximately 20 minutes. Collect the supernatants carefully. When examining the components within the cell, use PBS (pH 7.2-7.4) to dilute cell suspension to the cell concentration of approximately 1 million/ml. Damage cells through repeated freeze-thaw cycles to let out the inside components. Centrifuge at 2000-3000 RPM for approximately 20 minutes.

 

Tissue and other body fluids Rinse tissues in PBS (pH 7.4) to remove excess blood thoroughly and weigh before homogenization. Mince tissues and homogenize them in PBS (pH7.4) with a glass homogenizer on ice. Thaw at 2-8°C or freeze at -20°C. Centrifuge at 2000-3000 RPM for approximately 20 minutes.

 

*Sample can't be diluted with this kit. Owing to the the material we use to prepare the kit, the sample matrix interference may falsely depress the specificity and accuracy of the assay.

 

Assay Procedure

1. Prepare all reagents, standard solutions and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature.

2. Determine the number of strips required for the assay. Insert the strips in the frames for use. The unused strips should be stored at 2-8°C.

3. Add 50μl standard to standard well. Note: Don’t add antibody to standard well because the standard solution contains biotinylated antibody.

4. Add 40μl sample to sample wells and then add 10μl anti-ANG-4 antibody to sample wells, then add 50μl streptavidin-HRP to sample wells and standard wells ( Not blank control well ). Mix well. Cover the plate with a sealer. Incubate 60 minutes at 37°C.

5. Remove the sealer and wash the plate 5 times with wash buffer. Soak wells with at least 0.35 ml wash buffer for 30 seconds to 1 minute for each wash. For automated washing, aspirate all wells and wash 5 times with wash buffer, overfilling wells with wash buffer. Blot the plate onto paper towels or other absorbent material.

6. Add 50μl substrate solution A to each well and then add 50μl substrate solution B to each well. Incubate plate covered with a new sealer for 10 minutes at 37°C in the dark.

7. Add 50μl Stop Solution to each well, the blue color will change into yellow immediately.

8. Determine the optical density (OD value) of each well immediately using a microplate reader set to 450 nm within 10 minuets after adding the stop solution.

 

Calculation of Result

Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.

Contact Details
Shanghai Korain Biotech Co., Ltd

Contact Person: Lee

Send your inquiry directly to us (0 / 3000)